Huawei TaiShan X6000 User Manual page 13

Hide thumbs Also See for TaiShan X6000:
Table of Contents

Advertisement

TaiShan X6000 Server
User Guide
Table 2-3 Indicators and buttons on the X6000 front panel
No.
1
2
3
Issue 04 (2020-06-05)
Silks
Name
cree
n
Server node
1 health
indicator
Server node
2 health
indicator
UID button/
indicator
Copyright © Huawei Technologies Co., Ltd.
Description
● Off: There is no power supply, or the PSU is
faulty.
● Blinking red at 1 Hz: A major alarm has been
generated on the server node.
● Blinking red at 5 Hz: A critical alarm has been
generated on the server node.
● Steady green: The server node is operating
properly.
● Off: There is no power supply, or the PSU is
faulty.
● Blinking red at 1 Hz: A major alarm has been
generated on the server node.
● Blinking red at 5 Hz: A critical alarm has been
generated on the server node.
● Steady green: The server node is operating
properly.
The UID button/indicator helps identify and locate
a server node in a chassis. You can turn on or off
the UID indicator by pressing the UID button or
by remotely running a command on the iBMC CLI.
UID indicator
● Off: The server node is not being located.
● Steady blue: The server node has been located.
● Blinking blue: The server node has been
located and is differentiated from other nodes
that have also been located.
UID button
● You can press this button to turn on or off the
UID indicator.
● You can press and hold down this button for 4
to 6 seconds to reset the iBMC.
2 Components
6

Advertisement

Table of Contents
loading

Table of Contents