Limited Warranty; Classifications And Ratings - Wallbox Supernova Installation Manual

Hide thumbs Also See for Supernova:
Table of Contents

Advertisement

GETTING STARTED
Safety Instructions
• In no event shall WALLBOX be liable for direct, indirect, special, incidental, or consequential
damages arising from use or installation of any software or hardware described in this document.
• This document is originally written in English. Other language versions are a translation of
the original document and WALLBOX cannot be held liable for errors in the translation.
• This document and parts thereof must not be reproduced or copied without
written permission from WALLBOX, and the content thereof must not be
imparted to a third party nor used for any unauthorized purpose.

Limited Warranty

• Wallbox warrants this product against defects in materials and
workmanship for a period of 3 years from the date of purchase.
• During this period, at its discretion, Wallbox will either repair or
replace any defective product at no charge to the owner.
• Replacement products or repaired parts will be guaranteed for only the
unexpired portion of the original warranty or 2 years whichever is greater.
• Any defect resulting from any accident, misuse, improper maintenance,
or normal wear and tear is not covered bzy the limited warranty.
• Substitution or incorporation of any part by the client will be considered as incorrect usage.
• Except to the extent permitted by applicable law, the terms of this limited warranty
do not exclude, restrict, or modify, and are in addition to, the mandatory statutory
rights applicable to the sale of the product to you. If you believe your product is
defective, contact Wallbox for instructions on where to send or bring it for repair.
10
GETTING STARTED
Safety Instructions

Classifications and Ratings

Type of construction:
External design:
Mounting method:
Installation location:
Location accesses:
Intended for use:
Type of EV Supply Equipment
Rated Voltage
Rated Frequency (fn)
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Temporarty Overvoltage
Rated peak withstand current (Ipk):
Rated conditional short-circuit current (Icc):
Rated diversity factor (RDF):
Pollution degree:
Electromagnetic compatibility
(EMC) classification:
EV supply equipment connection:
Charging Mode:
Intended Use
Fixed parts.
Floor-Standing Assembly
Stationary equipment mounted on concrete
Indoor and outdoor use.
Equipment for locations with non-
restricted access and restricted access.
Equipment intended for use by ordinary persons.
Electric Ratings
Regulated D.C. EV charging station by
means of controlled current (up to 150A)
charging D.C. output voltage rating
category: 150 Vdc to 500 Vdc.
400V (-/+10%)
50Hz
1430 Vrms
2500 Vrms
1500V
130 A
10kA
1
Pollution degree 3. Internally reduced
to degree 2 in the main enclosure.
For emissions residential (Class B)
and for immunity non-residential.
Electric Architecture
EV supply equipment (AEVCS) permanently
connected to the AC mains supply network.
DC EV supply equipment Charging Mode
4, both System A (Chademo) and System
C (CCS), plus Case C connection.
11