36
PRE-OPERATING PREPARATIONS
ENOM00041-B
Warning indicators, faults and remedy
Sound
1 sec.
Continuous
*2
Continuous
*2
Continuous
Intermittent
*2
short beep
Remarks
*1: Remote control model and multi-tiller handle model: The buzzer and lamp (LED) are activated when the
key is turned on.
6
Basic tiller handle model: The buzzer and lamp (LED) are activated when pulling the recoil starter or
running the starter motor.
*2: It is necessary to stop the engine, if you want to reset the warning system.
High speed ESG (Electronic Safety Governor)
High speed ESG is a device to prevent over revolution of the engine. If the load to the engine becomes light for
some reason, it runs at a higher speed than the usual. In such the case, the buzzer sounds and the ESG is
activated not to ignite the spark plug. Therefore, the engine speed varies and is controlled following specified
engine speed.
MFS 30D: 6700 min
MFS 25D: 6200 min
Low speed ESG
Low speed ESG is a device to prevent the engine from getting damage. If the engine has problems regarding
cooling water, oil pressure, and sensors, the low speed ESG is activated not to ignite the spark plug, and disable
fueling. Therefore, the engine speed varies and is controlled under 2800min
Warning indicators
Low
Lamp (LED)
speed
ESG
1 sec.
ON
*2
*2
ON
ON
*2
*2
ON
ON
*2
*2
Blinking
ON
-1
(rpm)
-1
(rpm)
High
Description of faults
speed
ESG
Normal system test when start up.
Engine speed exceeds maximum
ON
allowable RPM
Low oil pressure
Cooling water Temperature is high.
Water temp or MAP sensor out of
range
-1
(rpm).
Remedy
*1
1
2
3
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfs 30d

Table of Contents