Christie CineLife+ CP4415-RGB Installation And Setup Manual page 64

4k-rgb
Hide thumbs Also See for CineLife+ CP4415-RGB:
Table of Contents

Advertisement

5. In step 1 of the Sensor-to-screen Calibration wizard, set the maximum brightness and color
point.
a) Enable the Display White Test Pattern option.
b) To set the maximum expected room and chiller (for chiller-based products) temperatures,
use the plus (+) or minus (-) signs.
c) Adjust the RGB sliders to set thebrightness and color point.
d) Select Next.
6. Wait 20 minutes for the projector to stabilize or select Skip during the stabilization time
period.
7. In step 2 of the Sensor-to-screen Calibration wizard, measure and enter the screen values.
a) To trigger the measurement at a specific operating point, under Sensor to screen, select
Capture.
The Capture button changes color to indicate the capture process is activated. Only one
Capture button is active at a time but the buttons can be selected in any order.
The projector automatically sets the red, green, and blue output laser powers to the pre-
determined settings calculated and displayed in the Drive Percentage (Calculated) area of
the wizard.
A 10 second countdown begins to allow the projector white point and brightness to
stabilize and no changes can be made. At the end of the count down period, the Color
Sensor values fields are automatically populated by the projector for the currently selected
drive percentage value.
b) When the countdown ends, take x, y, and fL measurements using the spectroradiometer.
Christie recommends taking meter readings from the center of the screen to obtain
accurate screen measurements.
c) Under Measured Values, using the numeric keypad record the associated
spectroradiometer values for x, y, and fL.
The projector holds the on-screen color and brightness level until the same or another
Capture button is selected.
d) Repeat steps a to c for the remaining drive percentage set points until all x, y, and fL
values are entered.
Spectroradiometer measurements can be captured in any order but all three x, y, and fL
measurements must be entered before moving onto the next capture. You can recapture a
specific measurement at any time during the process by selecting the Capture button. In
this case, the measured spectroradiometer and color sensor values are reset.
e) Once all the color sensor and measured values are entered for all nine rows, select Apply
and Save.
8. Verify and complete the calibration.
a) Select a white point to measure by selecting either the DCI, D65, or Custom white point
buttons.
Once selected, the projector automatically enables LiteLOC, selects a White test pattern
with uncorrected colors at the white point specified, and sets the brightness to 80%.
b) Using a spectroradiometer, measure screen X and Y values at the center of the screen.
To verify the calibration has been successfully applied, the measured white point must be
within the expected tolerance.
c) When complete, select Finish.
CineLife+ 4K-RGB Installation and Setup Guide–CP4415-RGB, CP4420-RGB, CP4425-RGB, CP4435-RGB
020-103244-06 Rev. 1 (06-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Managing the light source
64

Advertisement