For instance:
Dip1
Dip2
0
0
1
0
0
1
Console
For manufacturer or professional engineer to debug or service.
Pin3
232-TX
Pin4*
+5~+12V for wake up
Pin5*
GND for wake up
Pin6
232-RX
Pin8
232-GND
*Wake up signal shall ≥0.5Sec, current between 5~15mA. After send wake up signal, the
voltage shall disappear for normal operation.
Contact
Pin1
Input, passive signal. On: turn off battery. Off: normal.
Pin2
Pin3
Output1. On: stop charge.
Pin4
Pin5
Output2. On: stop discharge.
Pin6
Pin7
Output3. On: BMS error.
Pin8
Input terminals: BMS provide 5Vdc internally. External contactor control ON/OFF.
Output terminals: BMS control ON/OFF. External source request signal voltage ≤25V, current <0.3A.
Dip3
Dip4
0
0
0
0
0
0
The
corresponding
position of switch
11
Status
RS485:115200
CAN terminal resistance:
connected
RS485:9600
CAN terminal resistance:
connected
RS485: 115200
CAN terminal resistance:
disconnected.
+
-
+
-
+
-