Examples of Slot Use

Intentionally Empty Slot
If a slot is intentionally left empty:
In the absence of other modules, the Gateway will not log Module Status for this slot position.
Correct Module Fitted
If a module is fitted that matches the Bound Unit ID, the User-Defined Name will be used in
the network browser.
In the absence of other modules, the Gateway will log Module Status as OK, and display
Module Status = OK on the Logging page (see
PRESENT for the slot position.
Module Absent - Unit Bound
If a slot is intended to have a particular module fitted (as set by the Bound Unit ID function),
but no module is fitted, the Unit Type field will display No Unit Fitted and the Unit ID field will
display No Unit. However, the User-Defined Name field will show the intended name and the
Bound Unit ID field will display the intended ID.
In the absence of other modules, the Gateway will log Module Status as 1 Module Missing,
and show Module Status = 1 Module Missing on the Logging page (see
Gateway also logs MSG=UNIT LOST for the slot position.
Module Fitted - No Unit Bound
If a module is fitted in a slot but no Bound Unit ID is assigned to the slot, the generic type
name for the module type will be displayed, and the slot will appear in the network browser by
its slot number and generic type.
In the absence of other modules, the Gateway will log Module Status as 1 Extra Module, and
show Module Status = 1 Extra Module on the Logging page (see
logs MSG=UNIT PRESENT for the slot position.
Incorrect Module Fitted
If a module is fitted that does not match the Bound Unit ID, the User-Defined Name will not
be used and the generic type and slot number will appear in the network browser.
In the absence of other modules, the Gateway will log Module Status as 1 Extra Module, and
show Module Status = 1 Extra Module on the Logging page (see
logs MSG=UNIT PRESENT for the slot position.
Non-RollCall Module Fitted
If a card that is passive to RollCall is fitted in a slot, select the Non-RollCall Enable check box.
The Gateway will simulate a RollCall compatible card in the relevant slot, and raise awareness
to RollLog and RollMap. In the IDNAME field, enter a name for the unit so that it can be
recognized.
For the module, the Gateway will log MSG=NON ROLLCALLMODULE, and
IDNAME=<user defined>.
54
• BadType: Module in slot is not expected type.
• Extra: Module in slot but no module expected in this position.
• --: No module fitted and no module expected in this slot.
• The Unit Type field will show No Unit Fitted, and the Unit ID field will show No Unit.
• The User-Defined Name field will be empty and the Bound Unit ID window will display
None.
62). The Gateway also logs MSG=UNIT
page
page
page
page
62). The
62). The Gateway also
62). The Gateway also