Installing A New Module; Removing A Module; Replacing A Module In A Live Environment - GRASS VALLEY IQH4B User Manual

Table of Contents

Advertisement

Installing a New Module

Before installing a new module, consult the Power Rating Table on the previous page to ensure
there is adequate power available.
To install a new module:

Removing a Module

To remove a module:
If a different type of module is to be installed in this position, proceed as in Installing a New
Module.
If the slot is to be left vacant, proceed as follows:

Replacing a Module in a Live Environment

Grass Valley recommends that the mains connections are removed before performing the
operations described above. However, in a live environment this may not be possible, so the
modules are designed to be removed and installed without switching the power off.
32
Note: Ensure that the mains power connection at the rear of the unit is
removed before these operations are performed.
1 Open the front panel.
2 Remove the module retaining bar.
3 Choose an empty slot position for the module.
4 At the rear of the enclosure remove the screws securing the blanking plate associated with
the chosen slot position. Store the blanking plate in a safe place for future use.
5 Ensuring correct orientation, fit the rear connecting panel (supplied with the new module)
to the rear of the enclosure in the vacant aperture and secure with the fixing screws
provided.
6 At the front of the enclosure, (ensuring correct orientation) carefully slide in the new
module until it fully mates with the rear connector panel.
7 Refit the module retaining bar.
8 Close the front panel.
9 Update the Power Rating table on the previous page.
Note: Ensure that the mains power connection at the rear of the unit is
removed before these operations are attempted
1 Open the front panel.
2 Remove the module retaining bar.
3 Carefully slide out the desired module.
4 Refit the module securing bar.
5 Close and secure the front panel.
6 At the rear of the enclosure, fit the blanking plate in the appropriate position using two
screws.
7 Update the Power Rating table.
:
Note: It cannot be guaranteed that there will be no disturbance to the
operation of other modules in the enclosure if a module is replaced
without first powering down the enclosure.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iqrcg00

Table of Contents