YASKAWA Varispeed V7 Instruction Manual page 94

Compact general-purpose inverter
Table of Contents

Advertisement

Data
Name
Byte 1,
Terminal
bit 3
S4
Byte 1,
Terminal
bit 5
MA*
Byte 1,
Terminal
bit 6
P1
Byte 1,
Terminal
bit 7
P2
Bytes
Speed
2 and 3
Actual
Bytes
Output
6 and 7
Current
Monitor
* Terminal MA can be used only from DeviceNet communications. There is
no corresponding external output terminal.
6. Operating with DeviceNet Communications
Indicates the input status of Inverter
multi-function input terminal S4. When
using this terminal as a general-purpose
DI terminal, always set Inverter constant
n053 to 28.
0: Terminal S4 OFF
1: Terminal S4 ON
Indicates the output status of Inverter
multi-function output terminal MA.
0: Terminal MA OFF
1: Terminal MA ON
Indicates the output status of Inverter
multi-function output terminal P1.
0: Terminal P1 OFF
1: Terminal P1 ON
Indicates the output status of Inverter
multi-function output terminal P2.
0: Terminal P2 OFF
1: Terminal P2 ON
Indicates the Inverter's speed.
The units depend on the setting in
Inverter constant n035.
The units are not affected by the speed
scale (SS) setting.
Indicates the Inverter's output current.
The units are fixed at 0.1 A. The units
are not affected by the current scale
(CS) setting.