YASKAWA Varispeed V7 Instruction Manual page 114

Compact general-purpose inverter
Table of Contents

Advertisement

In-
At-
Name
stance
tribute
01
10
Input
Voltage
11
Output
Voltage
12
Accelera
tion
Time
13
Decelera
tion
Time
14
Low Spd
Limit
15
High
Spd Lim-
it
6. Operating with DeviceNet Communications
Contents
Indicates the
Inverter's input
voltage.
Minimum units: V/
VS
2
VS
: Voltage scale
(attribute 1B)
Indicates the
Inverter's output
voltage.
Minimum units: V/
VS
2
VS
: Voltage scale
(attribute 1B)
Sets or references
the Inverter's Ac-
celeration Time 1
(n019).
Minimum units: ms/
TS
2
TS
: Time scale (at-
tribute 1C)
Sets or references
the Inverter's De-
celeration Time 1
(n020).
Minimum units: ms/
TS
2
TS
: Time scale (at-
tribute 1C)
Sets or references
the Inverter's Fre-
quency Reference
Lower Limit (n034).
(See notes 2 and
3.)
Minimum units: r/
SS
min/2
SS
: Speed scale
(attribute 16)
Sets or references
the Inverter's Fre-
quency Reference
Upper Limit (n033).
(See notes 2 and
3.)
Minimum units: r/
SS
min/2
SS
: Speed scale
(attribute 16)
Setting
Factory Set-
Range
ting (Hex)
---
00C8 (200
V) or 0190
(400 V)
---
0000
0 to
2710 (10.0
6,000
s)
s
0 to
2710 (10.0
6,000
s)
s
0 to
0000
110%
of the
max.
fre-
quen-
cy
0 to
0708
110%
(1,800 r/m)
of the
max.
fre-
quen-
cy
Read Write
Size
OK
---
Word
OK
---
Word
OK
OK
Word
OK
OK
Word
OK
OK
Word
OK
OK
Word
113