YASKAWA Varispeed V7 Instruction Manual page 106

Compact general-purpose inverter
Table of Contents

Advertisement

Service
Service Name
Code
(Hex)
10
Set_Attribute_
Single
05
Reset
• Object Contents
In-
At-
Name
stance
tribute
00
01
Object
Soft-
ware
Revision
01
03
Run1
04
Run Rev
05
NetCtrl
06
State
6. Operating with DeviceNet Communications
Changes the contents of the speci-
fied attribute.
Resets the Inverter.
Contents
Indicates the Con-
trol Supervisor ob-
ject's software
revision.
Runs the Inverter
forward.
00: Stop.
01: Run forward.
Runs the Inverter
in reverse.
00: Stop.
01: Run in re-
verse.
Sets the RUN
command right.
00: Use the RUN
command input
method set in con-
stant n003 (RUN
Command Selec-
tion).
01: Enables the
RUN command
from DeviceNet
(byte 0, bits 0 and
1).
Indicates the
Inverter's status.
02: Inverter prepa-
ration not complet-
ed.
03: Inverter prepa-
ration completed
(stopped).
04: Operating
(normal).
05: Decelerated to
a stop (normal).
06: Decelerated to
a stop because of
serious fault.
07: Stopped be-
cause of serious
fault.
Description
Setting
Factory Set-
Range
ting (Hex)
---
0001
00,01
00
00,01
00
00,01
00
---
03
Read Write
Size
OK
---
Word
OK
OK
Byte
OK
OK
Byte
OK
OK
Byte
OK
---
Byte
105

Advertisement

Table of Contents
loading

Table of Contents