YASKAWA Varispeed V7 Instruction Manual page 246

Compact general-purpose inverter
Table of Contents

Advertisement

Second Functions (Constants n050 to n079)
No.
Register
No. for
Trans-
mission
050
0132
Multi-function Input Se-
lection 1 (Terminal S1)
051
0133
Multi-function Input Se-
lection 2 (Terminal S2)
052
0134
Multi-function Input Se-
lection 3 (Terminal S3)
053
0135
Multi-function Input Se-
lection 4 (Terminal S4)
054
0136
Multi-function Input Se-
lection 5 (Terminal S5)
055
0137
Multi-function Input Se-
lection 6 (Terminal S6)
056
0138
Multi-function Input Se-
lection 7 (Terminal S7)
057
0139
Multi-function Output Se-
lection 1
058
013A
Multi-function Output Se-
lection 2
059
013B
Multi-function Output Se-
lection 3
064
0140
Processing During Ana-
log Frequency Refer-
ence Loss
068
0144
Analog Frequency Ref-
erence Gain
069
0145
Analog Frequency Ref-
erence Bias
070
0146
Analog Frequency Ref-
erence Filter Time Con-
stant
071
0147
Analog Frequency Ref-
erence Gain
072
0148
Analog Frequency Ref-
erence Bias
073
0149
Analog Frequency Ref-
erence Filter Time Con-
stant
077
014D
Multi-function Analog In-
put Function
078
014E
Multi-function Analog In-
put Signal Selection
079
014F
Sequence Input Double
Reading Selection
Name
Setting
Range
1 to 28
1 to 28
0 to 28
1 to 28, 34
1 to 28
1 to 28
1 to 28
0 to 21
0 to 21
0 to 21
0: Process-
ing dis-
abled
1: Process-
ing
enabled
−255% to
255%
−100% to
100%
0.00 to
2.00 s
−255 to
255
−100% to
100%
0.00 to
2.00 s
0 to 4
0, 1
0, 1
10. Specifications
Setting Unit
Factory
Setting
1
1
1
2
1
3
1
5
1
6
1
7
1
10
1
2
1
1
1
0
1
0
1%
100%
1%
0%
0.01 s
0.10 s
1%
100%
1%
0%
0.01 s
0.01 s
1
0
1
0
1
0
User
Ref.
Setting
Page
159
159
159
159
159
159
159
164
164
164
---
---
---
---
---
---
---
162
164
---
245

Advertisement

Table of Contents
loading

Table of Contents