Multi-function Analog Input Signal Selection (n078)
Constant
No.
n078
Using Output Signals (n057, n058, n059)
The functions of multi-function output terminals MA, P1 and P2 can be
changed as necessary by setting constants n057, n058, and n059.
• Terminal MA function: Set in n057
• Terminal P1 function: Set in n058
• Terminal P2 function: Set in n059
Note: Terminal MA can be used only from DeviceNet communications. There
is no corresponding external output terminal.
Setting
0
1
2
3
4
5
6
7
164
Name
Multi-function Analog
Input Signal Selection
Name
Fault
Operating
Frequency agree
Zero speed
Frequency detection 1
Frequency detection 2
Overtorque detection,
NO contact output
Overtorque detection,
NC contact output
Unit
Setting Range
1
0=Digital Operator ter-
minal (voltage: 0 to
10 V)
1=Digital Operator ter-
minal (current 4 to
20 mA)
Description
Closed when Inverter fault oc-
curs.
Closed when either FWD/REV
command is input or voltage is
output from the Inverter.
Closed when the set frequency
agrees with Inverter output fre-
quency.
Closed when Inverter output fre-
quency is less than minimum out-
put frequency.
Output frequency ≥ Frequency
Detection Level (n095)
Output frequency ≤ Frequency
Detection Level (n095)
-
-