Rcp Operational Tests - Kannad 406 AF-COMPACT Installation Manual

406 mhz emergency locator transmitter 121.5 mhz homing frequency
Hide thumbs Also See for 406 AF-COMPACT:
Table of Contents

Advertisement

error conditions were found.
• A series of short flashes indicates the test has failed.
Remark: The number of flashes gives an indication of the faulty
parameter detected during the self-test.
3+1
LOW BATTERY VOLTAGE
3+2
LOW RF POWER
3+3
FAULTY VCO LOCKING (FAULTY FREQUENCY)
3+4
NO IDENTIFICATION PROGRAMMED
If self-test fails, contact the distributor as soon as possible.
Unless a waver is granted, flight should be cancelled.
B. RCP operational tests
Check correct operation of RCP LED
annunciator by switching ELT and RCP as
described in the sequential procedure
19: RCP LED operation
"ARM" position).
INITIAL INSTALLATION MANUAL
KANNAD 406 AF-COMPACT / KANNAD 406 AF COMPACT ER
(with ELT switch in the
Figure
Figure 19: RCP LED operation