Download Print this page
Kannad 406 AF-COMPACT Service Letter

Kannad 406 AF-COMPACT Service Letter

Hide thumbs Also See for 406 AF-COMPACT:

Advertisement

Quick Links

Compatibility of Kit, Remote Control Panel RC100
1. REASON
PACK ELT KANNAD 406 AF-COMPACT (P/N S1840501-02) including KANNAD 406 AF-COMPACT
transmitter (P/N S1840501-01) is supplied with RC200 Remote Control Panel (P/N S1820513-11) included
in KIT, REMOTE CONTROL PANEL, RC200-COMPACT (P/N S1820513-20).
Some customers may choose to install a RC100 Remote Control Panel Kit (P/N S1820513-03) instead of
RC200 Remote Control Panel.
This Service Letter is to provide information regarding the way to install a RC100 Remote Control Panel
connected to KANNAD 406 AF-COMPACT transmitter (P/N S1840501-01).
2. EFFECTIVITY
PACK ELT KANNAD 406 AF-COMPACT S1840501-02
Remote Control Kit, RC100
3. ASSEMBLY PROCEDURE
A. General
CAUTION: IF THE ELT HAS TO BE CONNECTED TO AN RC100 RCP ALREADY IN PLACE, BE AWARE
THAT THE CONNECTION OF AN RC100 RCP INSTALLED WITH A KANNAD 406 AF-
COMPACT IS DIFFERENT FROM AN RC100 RCP CONNECTED WITH ANOTHER TYPE OF
KANNAD ELT (S182X502-XX OR S181X502-XX).
CONNECTION OF RC100 RCP WITH KANNAD ELT (S182X502-XX OR S181X502-XX)
REQUIRES A 4-WIRE BUNDLE.
CONNECTION OF RC100 RCP WITH KANNAD 406 AF-COMPACT REQUIRES A 3-WIRE
BUNDLE.
DO NOT USE THE PREVIOUS CONNECTION AND CONNECT IT ACCORDING TO
Wiring Diagram of RC100 RCP with KANNAD 406
B. RC100 RCP Assembly
Assemble the items included in RC100 Kit as shown
in Installation Manual DMA 180 supplied with the Kit.
Note: this drawing (S1820825) is supplied with RC100 Remote Control Panel Kit.
C. Connection of RC100 to ELT transmitter
Connect the RCP to the ELT transmitter according to
406 AF-COMPACT
Note: this drawing (S1820420) is supplied with RC100 Remote Control Panel Kit.
(1) Connect Pin 1 of switch to Resistor R1.
(2) Connect the other side of Resistor R1 to A of DIN12 connector (supplied with PACK S1840501-02) and
to Pin 3 of switch.
(3) Connect Pin 2 of switch to G of DIN12 connector (supplied with PACK S1840501-02) and to any leg of
the led (bipolar led).
(4) Connect the other leg of the led to J of DIN12 connector (supplied with PACKS1840501-02).
Date: JUL 07/2008
REV.: 01
© KANNAD 2008
PACK ELT KANNAD 406 AF-COMPACT
S1820513-03
Figure 1: Assembly of RC100 RCP
Figure 2: Wiring Diagram of RC100 RCP with KANNAD
SL_S1840501-25-01
SERVICE LETTER
KANNAD
Emergency Locator Transmitter
Emergency Locator Transmitter
Remote Control Panel
AF-COMPACT.
Figure 2:
and as described
Page: 1 of 4

Advertisement

loading

Summary of Contents for Kannad 406 AF-COMPACT

  • Page 1 CAUTION: IF THE ELT HAS TO BE CONNECTED TO AN RC100 RCP ALREADY IN PLACE, BE AWARE THAT THE CONNECTION OF AN RC100 RCP INSTALLED WITH A KANNAD 406 AF- COMPACT IS DIFFERENT FROM AN RC100 RCP CONNECTED WITH ANOTHER TYPE OF KANNAD ELT (S182X502-XX OR S181X502-XX).
  • Page 2 SERVICE LETTER KANNAD Emergency Locator Transmitter D. Diagrams Figure 1: Assembly of RC100 RCP SL_S1840501-25-01 Date: JUL 07/2008 REV.: 01 Page: 2 of 4 © KANNAD 2008...
  • Page 3 SERVICE LETTER KANNAD Emergency Locator Transmitter Figure 2: Wiring Diagram of RC100 RCP with KANNAD 406 AF-COMPACT E. Check Check correct operation of RCP led annunciator by switching ELT and RCP as described in the sequential procedure Figure 3: RCP led operation.
  • Page 4 For any further information, please feel free to contact our customer support at: KANNAD SAR Line of Products Zone Industrielle des Cinq Chemins 56520 GUIDEL FRANCE E-mail: support.sar@kannad.com Tel.: +33 (0)2 97 02 49 00 SL_S1840501-25-01 Date: JUL 07/2008 REV.: 01 Page: 4 of 4 © KANNAD 2008...

This manual is also suitable for:

S1840501-02