- Solder the DIN12 connector or Programming Dongle on the other side
of the bundle (pins A, G, J):
• Connect the wire from cathode (short leg) of LED to pin J of DIN12
connector;
• Connect the wire from resistor to pin A of DIN12 connector;
• Connect the wire from pin 2 of switch to pin G of DIN12 connector.
• Connect the anode (long leg) of LED to pin 2 of switch.
Figure 13: Wiring of 3-wire bundle between RC100 and ELT
(2) RC102
CAUTION: RC102 RCP may only be installed with KANNAD 406 AF
COMPACT P/N S1840501-01 at amendment M or higher or on
KANNAD 406 AF COMPACT ER P/N S1840501-04. A WARNING label
is supplied with the kit and must be stuck on the 2-wire bundle on the
ELT side.
RC102 RCP is supplied as a kit
diagram). 2 types of front plates may be installed. Choose the appropriate
front plate according to the aircraft's instrument panel. The kit includes
also 2 LEDs. The white LED is a NVG LED (Night Vision Goggles) only
used for military aircraft, the red LED is a standard LED.
CAUTION: use NVG LED only for military aircraft equipped for night
vision googles. Never install this LED in RCP for standard aircraft.
Connection of RC102 requires a 2-wire bundle. A pin-to-pin wiring has to
be provided by the installer with AWG24 wires. Shielded wires are
recommended.