Battery discharges repeatedly
Measure the voltage across the battery, it
should then be in the range 12-13V. Then
start the engine at full throttle. Does the
voltage increase to> 14V?
NOT
Is the engine electrical connections OK?
YES
Replace the charge regulator
The engine does not stop
Does the engine stop when the
work equipment is activated while
you leave the seat?
NOT
Check short circuit cable and its
connection to the engine
Electric height adjustment does not work
Does the height adjustment work in
one direction?
YES
Replace the switch
Stop the engine, the ignition switch should
be in the off position. Is there voltage on the
YES
YES
Replace ignition
switch
NOT
Replace ignition switch
YES
NOT
Connect battery voltage directly to
the actuator, switch the plus and
minus cable. Does the actuator
work in both ways?
YES
shut off valve / ground?
NOT
Change the battery
Repair the fault
NOT
Chapter
7 Electrical system
Switch the actuator
Page