Ambient conditions
Pollution degree
Biological ambient conditions:
Chemically active environmental
conditions
Mechanically active environmental
conditions
Vibratory load
- D410-2
- S120 (without SME/DME)
Shock load
- D410-2
- S120 (without SME/DME)
Note
Observe the fields of application of the Power Modules along with their derating. Refer
to SINAMICS S120 for AC Drives Manual.
Vibration reduction
If SIMOTION D410-2 is subjected to larger shocks or vibrations, you must use suitable measures
to reduce the acceleration or the amplitude.
We recommend installation on shock-absorbing material (e.g. rubber-metal vibration dampers).
Other data
Condition
Protection against the ingress of for‐
eign matter and water
Class of protection
SIMOTION D410-2
Equipment Manual, 07/2021, A5E33446720B
Fields of application
2 according to EN 60664‑1:2008
Class 3B1 according to
EN 60721‑3‑3:1995
Class 3C1 according to
EN 60721‑3‑3:1995
Class 3S1 according to
EN 60721‑3‑3:1995
Vibratory load during operation ac‐
cording to EN 60721-3-3: Class 3M1
Shock load during operation accord‐
ing to EN 60721-3-3: Class 3M1
Field of application
IP20 degree of protection according to EN 60529
Class 1 (with protective conductor system) and class 3 (PELV) ac‐
cording to EN 61800‑5‑1:2007
5.2 Ambient conditions
Remarks
Mold, mold growth, slime, rodents, termites and
other animal vermin are not permissible
Conductive dusts are not permitted.
Test values according to EN 60068-2-6 (sinusoi‐
dal)
10 ... 57 Hz: 0.075 mm deflection amplitude
57 ... 150 Hz: 1 g acceleration amplitude
10 frequency cycles per axis
Test values according to EN 60068-2-27 (half-si‐
nusoidal)
5 g peak acceleration, 30 ms duration
3 shocks in all three axes in both directions
Technical data
83