Siemens SIMOTION Equipment Manual page 25

Hide thumbs Also See for SIMOTION:
Table of Contents

Advertisement

Component
SIMATIC ET 200SP
SIMATIC ET 200S
SIMATIC ET 200AL
SIMATIC ET 200pro
SIMATIC ET 200eco
Other PROFIBUS I/O
Gateways
Drive interfaces
Drive units with PROFIBUS DP
interface
(e.g. CU310-2 DP)
Teleservice adapter
PROFINET IO
The SIMOTION D410‑2 DP/PN can communicate with the following components via the onboard
PROFINET IO interface.
Table 2-3
Components on the PROFINET IO
Component
Programming device (PG/PC)
SIMATIC HMI device
Other controllers (e.g. SIMOTION or SI‐
MATIC)
Master computer
Distributed I/O systems
SIMATIC ET 200MP
SIMOTION D410-2
Equipment Manual, 07/2021, A5E33446720B
Function
Finely scalable I/O system for cabinet installation; ET 200SP features a single-cable and multi-
cable connection with push‑in terminals, compact dimensions, high performance, and low
part variety.
Finely scalable I/O system for cabinet installation and particularly time-critical applications;
including motor starters, safety technology and individual grouping of load groups.
Modular, distributed I/O system with compact I/O modules in IP65/67; simple installation in
all mounting positions even in small spaces; front and transverse screw fastenings on flat
surfaces or on aluminum supporting channels; flexible connection to PROFINET or PROFIBUS
or simple integration in SIMATIC ET 200SP.
Modular I/O system with IP65/IP67 degree of protection for machine-related applications with
no cabinet; with features such as more compact designs, integrated PROFIsafe safety tech‐
nology, PROFINET connection, and live module replacement.
I/O system with IP65/IP67 degree of protection for machine-related applications with no
cabinet, with a flexible and fast connection system in ECOFAST or M12.
DP/AS-Interface Link 20E and DP/AS-Interface Link Advanced for the PROFIBUS DP gate‐
way to AS-Interface
DP/DP coupler for connecting two PROFIBUS DP networks
ADI4 (Analog Drive Interface for 4 axes) for the connection of drives with analog ±10 V
setpoint interface or for external encoders
IM 174 (Interface Module for 4 axes) for the connection of drives with analog ±10 V
setpoint interface, external encoders or the connection of stepper drives with pulse/
direction interface
... convert speed setpoints into signals for controlling the motor and supply the power re‐
quired to operate the motors.
Can also be operated as an isochronous slave on the PROFIBUS DP.
Remote diagnostics
Function
... configures, assigns parameters, programs, and tests using the SIMOTION SCOUT
Engineering System (ES).
... is used for operating and monitoring functions. This is not an essential require‐
ment for the operation of a Control Unit.
... e.g. higher-level controller (plant controller); modular machine concepts with
multiple controllers, distributed across individual machine modules.
... communicates with other devices via UDP, TCP/IP.
Modular I/O system for cabinet installation and high channel densities in the SI‐
MATIC S7‑1500 packaging system. SIMATIC ET 200MP permits the shortest bus cycle
times and fastest response time even with large volumes of data. With the time-
based I/O, signals can be recorded or output to the precise µs.
Description
2.2 System components