Siemens SIMOTION Equipment Manual page 51

Hide thumbs Also See for SIMOTION:
Table of Contents

Advertisement

Interface assignment X21
Table 4-8
PROFIBUS DP/MPI interface (X21)
Representation
1
9
The 1P5 voltage is provided exclusively for the bus terminal.
No OLPs are permitted.
Signal type: VO = Voltage output (power supply); O = Output; B = Bidirectional
X24 interface assignment
Table 4-9
PROFIBUS DP interface X24 (SIMOTION D410‑2 DP only)
Representation
1
9
The 1P5 voltage is provided exclusively for the bus terminal.
No OLPs are permitted.
Signal type: VO = Voltage output (power supply); O = Output; B = Bidirectional
Connectable devices
The following devices can be connected to the PROFIBUS DP interfaces:
• PG/PC
• SIMATIC HMI devices
SIMOTION D410-2
Equipment Manual, 07/2021, A5E33446720B
Pin
Signal name
1
-
2
M
3
1RS_DP
4
1RTS_DP
5
1M
6
1P5
7
P24_SERV
8
1XRS_DP
9
-
Pin
Signal name
1
--
2
M
3
2RS_DP
4
2RTS_DP
5
1M
6
1P5
7
P24_SERV
8
2XRS_DP
9
--
Signal
Meaning
type
-
Reserved, do not use
VO
Ground to P24_SERV
B
RS-485 differential signal
O
Request to send
VO
Ground to 1P5
VO
5 V power supply for bus terminal, external, short-circuit proof
VO
24 V for teleservice, short-circuit proof, 150 mA maximum
B
RS-485 differential signal
-
Reserved, do not use
Signal
Meaning
type
--
Reserved, do not use
VO
Ground to P24_SERV
B
RS-485 differential signal
O
Request to send
VO
Ground to 1P5
VO
5 V power supply for bus terminal, external, short-circuit proof
VO
24 V for teleservice, short-circuit proof, 150 mA maximum
B
RS-485 differential signal
--
Reserved, do not use
Interfaces
4.3 PROFIBUS DP interfaces
51