6. Error Information

Error codes are shown continuously in the display when the fixture fails and they will not
disappear until the fixture is repaired.
1. Pan Reset Error
Check whether the position of the pan where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the pan operating range.
Check whether the Hall element on the pan is damaged.
Check whether the lead connecting the Hall element on the pan and the PCB board is in poor
contact or disconnected.
Check whether the motor on the pan is damaged.
Check whether the related circuit of the motor drive board on the pan is damage.
2. Pan Encoder Error
Check whether the encoder on the pan is damaged.
Check whether the lead connecting the encoder on the pan and the PCB board is in poor contact
or disconnected.
3. Tilt Reset Error
Check whether the position of the tilt where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the tilt operating range.
Check whether the Hall element on the tilt is damaged.
Check whether the lead connecting the Hall element on the tilt and the PCB board is in poor
contact or disconnected.
Check whether the motor on the tilt is damaged.
Check whether the related circuit of the motor drive board on the tilt is damage.
4. Tilt Encoder Error
Check whether the encoder on the tilt is damaged.
Check whether the lead connecting the encoder on the tilt and the PCB board is in poor contact or
disconnected.
5. CPU-B/C/D Error
Check whether the 485 (DATA) leads on the PCB board are installed in place or disconnected.
Check whether the related 485 (DATA) signal circuit on the PCB board is damaged.