Error Information - ACME AE-610 BEAM User Manual

Saber mini
Table of Contents

Advertisement

To select the Color Offset, press the ENTER button to show the COLOR OFFSET on the display.
Use the DOWN and UP button to adjust the value from -127 to 127, press the ENTER button to
store. Press the MENU button to exit.
GOBO OFFSET —Gobo home position adjustment
To select the Gobo 1 Offset, press the ENTER button to show the GOBO OFFSET on the display.
Use the DOWN and UP button to adjust the value from -127 to 127, press the ENTER button to
store. Press the MENU button to exit.
Prism OFFSET —Prism home position adjustment
To select the Prism Offset, press the ENTER button to show the PRISM OFFSET on the display.
Use the DOWN and UP button to adjust the value from 0 to 255, press the ENTER button to store.
Press the MENU button to exit.

4.3 Error Information

Lamp Startup Fail
It appears when there is no lamp or some wires are damaged.
Temperature Sense Error
It appears when temperature check board is damaged.
Lamp Too Hot Power Off
It appears when temperature is detected higher than 110℃. Check if the unit is properly ventilated,
or fans or temperature check board may is damaged.
Lamp Too Hot Low Power
It appears when temperature is detected higher than 105℃, the unit will run on a low power level.
Maintenance Fixture
It appears when the maintenance remaining time becomes 0S, please enter menu mode and reset
the time.
Lamp On Over 700 Hour
It appears when the lamp has been on over 700 hours, please turn off the lamp.
Memory Initial Fail
It appears when the memory IC is damaged.
11A