Maximum Temperature Setting
It may be necessary to adjust the maximum temperature for site
conditions to ensure safe showering from the unit. Ensure the hot water
temperature is at least 12°C above the required temperature for correct
operation of the thermostatic power shower.
To reset the maximum outlet temperature follow the sequence below :
1.
Turn the outer flow control
anticlockwise to maximum flow.
2.
Turn the inner temperature control
knob anticlockwise to the
maximum temperature stop. Do not
depress the override button.
3.
Check the shower temperature.
4.
If the maximum temperature
requires adjustment then remove
the flow and temperature control
knobs. Slide the end of the push-fit
release tool under the flow control
knob and lever the flow and
temperature
together, off the shower unit.
5.
Remove the small label covering
the retaining screw on the
temperature hub. Unscrew the
retaining screw and remove the
temperature hub.
Note! This will void the factory
setting.
control
knobs,
19
Maximum
Flow Position
Maximum
Temperature
Position
Inner Temperature
Control
Temperature Hub
4
Outer Flow
Control
T e m p e r a t u r e
Hub Retaining
Screw