Maintenance - Wickes AQUATRONIC POWER Product Manual

Thermostatic shower
Table of Contents

Advertisement

Malfunction
Pump does not stop
or change speed
when flow knob
turned.
Low or no water
flow.
Warning! There are no user serviceable components beneath the
cover of the appliance. Only a competent tradesperson should
remove the cover.
Before removing the cover the electricity supply must be turned off at
the mains and , if applicable, the appropriate circuit fuse removed. Mains
electrical connections are exposed when the cover is remove
Before replacing any parts ensure that the underlying cause of the
malfunction has been resolved.
Cleaning
Many household cleaners contain abrasives and chemical substances,
and should not be used for cleaning plated or plastic fittings. These
finishes should be cleaned with a mild washing up detergent or soap
solution, and then wiped dry using a soft cloth.
Cause
Potentiometer failure.
PCB failure.
Isolating valves closed.
Inlet filters blocked.
Appliance sited above
cold water storage
cistern.
Plumbing system fault
(airlock).
Blocked spray plate.

MAINTENANCE

26
Remedy
Renew the harness assembly.
Renew the PCB.
Open the isolating valves.
Clean the inlet filters.
The appliance is not suitable
for negative head installations.
Refer to INSTALLATION
REQUIREMENTS.
Reroute the pipework to avoid
airlock.
Clean the spray plate. Refer
to the instruction manual
supplied with the shower
fittings.