9.
Cut away and trim the thinned
section at the top or bottom of the
case to allow the electrical supply
cable to run down the rear of case.
10. Run the electrical supply cable in
surface mounted miniature
trunking (not supplied). Allow
sufficient cable to connect to the
terminal block (approximately
275 mm). Strip back approximately
30 mm of outer cable insulation.
Warning! Supply connections
must not be connected in reverse.
11. Hot and cold inlet supply
connections are:-
Hot – Left
Run the hot and cold water supply
pipes at 28 mm centres, ensuring
that the pipe ends project 30 mm
into the inlet manifold.
Caution! Do not use stainless steel
piping for inlet pipework.
Caution! If the pipework is chrome
plated remove all traces of chrome
from the connecting surfaces. If the
chrome is not removed then the inlet
manifold collets will not grip the
supply pipe.
12. Ensure that the end of the supply
pipework is cut squarely and is
free from burrs, which will
damage the inlet manifold seals.
Chamfer the end of the pipe to
assist insertion into the fitting and
prevent the 'O' seal tearing.
Cold – Right
15
Trim the thinned
section of the case
covering the cable
channel.
275
30
28
All dimensions in millimetres
Miniature
Trunking
30
H
C
Chamfer