SPECIFICATIONS

Electrical
Power Supply – 230–240 V at 50 Hz, fused at 3 Amps, via a double
pole fused switch (not supplied) with a minimum contact separation of
3 mm for each contact.
Electrical Connections – Terminal block will accept cable up to
2.5 mm². Minimum cable size (cross-sectional area) required under
2
normal installation conditions is 1 mm
.
Power Consumption – 150 W maximum.
Plumbing Connections
Inlet Connections – 2 x 15 mm Push-fit manifold.
Outlet Connection – 1/2" BSP male.
Operating Parameters
Cold Water Temperature – Maximum inlet temperature 30°C
Hot Water Temperature – Maximum inlet temperature 65°C
Warning! For safety reasons set the maximum temperature of the
stored hot water to between 60 and 65°C. Such temperatures are
considered sufficient to meet all normal requirements and will minimise
the deposition of scale in hard water areas.
Temperature Control – The maximum temperature stop is set to
41°C. Depressing the override button overrides the maximum
temperature and allows the showering temperature to be increased
by 5°C to approximately 46°C.
The showering temperature will be maintained to within 1°C of selected
temperature with a 10°C change in the hot or cold water supply.
If the cold supply fails the thermostatic mixer will shut down flow of water
to seepage levels in approximately 2 seconds. The hot supply must be
at least 12°C above the blend temperature for shut down to seepage to
occur.
The showering temperature will be maintained to within 1.5°C of the
selected showering temperature when the pressure between inlet and
outlet is halved on either the hot or cold side.
Operating Pressure
Minimum maintained pressure – 0.008 bar or 80 mm head of water.
Maximum maintained pressure – 0.5 bar.
Maximum static pressure – 1 bar or 10 m head of water.
8