16. Connect the live, neutral and earth
conductors of the electrical supply
cable to the terminal block in the
following manner.
L - Live terminal block
N - Neutral terminal block
- Earth terminal block
The supply cable earth connector
should be sleeved. Ensure that all
terminal connections are tight and
that no insulation is pinched.
17. Ensure the flow control gear wheel
is set to the off position. Turn the
gear wheel anticlockwise until the
gear drive microswitch emits a click
noise to indicate the gear drive is
in the off position.
18. Refit the unit cover and secure
with the three cover securing
screws.
19. Fit the flow control knob in the off
position.
20. Fit the temperature indicator trim
and temperature control knob.
21. The power shower will now require
commissioning.
COMMISSIONING.
22. Install the shower fittings. Refer to
the instruction manual supplied
with the fittings.