Malfunction
Low or no water flow. Isolating valves closed.
Fault Diagnosis – Installer Maintenance
The Thermostatic Power Shower is one part of an entire plumbing
system. The fitting of a pump places additional requirements on the
plumbing system. Some systems may require plumbing modifications
to allow them to cope with higher flow rates.
Providing the Thermostatic Power Shower has been correctly installed
and is operated as advised, difficulties should not arise. Fault diagnosis
and maintenance must be carried out by a competent person for whom
the fault diagnosis table is provided.
In the event of any of the following tests failing, re-check as appropriate before
contacting the Customer Service Department (Refer to Back Cover).
Malfunction
Shower runs for a
short time (30-60
seconds) then flow
reduces, splutters or
stops. Aggravated
when other hot taps
are in use. Less
evident on full cold.
Shower runs cool
after a short time
(1-2 minutes) then
flow splutters.
Cause
Inlet filters blocked.
Check
valve
incorrectly.
Appliance sited above
cold
water
storage
cistern.
Plumbing system fault
(airlock).
Cause
Air is being sucked down
the vent pipe, as the hot
take off to the shower is
too high up the pipe.
Air entering the hot
pipework.
24
Open the isolating valves.
Contact your installer.
fitted
Contact your installer.
The appliance is not suitable
for negative head installations.
Refer to INSTALLATION
REQUIREMENTS.
Contact your installer.
Refer to INSTALLATION
REQUIREMENTS for the
correct connection method.
Note the 1 metre hot takeoff
dimension. Consider increasing
the cold feed pipe to the cylinder
to 28mm diameter.
Refer to the plumbing system
diagram in the INSTALLATION
REQUIREMENTS for the correct
connection method.
Remedy
Remedy