Fault Diagnosis - User Maintenance
The appliance is fully performance tested after assembly. Providing it
has been correctly installed and is operated as advised, difficulties
should not arise. In the unlikely event that you experience problems
with your appliance then the following procedure will enable you to
undertake basic fault finding before contacting the person responsible
for installing your shower.
Malfunction
Maximum showering
temperature too hot.
Shower temperature
too cold.
Blend temperature
unstable.
Pump does not
operate.

FAULT DIAGNOSIS

Cause
Maximum temperature
incorrectly set.
Hot
water
cylinder
temperature less than
12°C above shower
temperature.
Maximum temperature
incorrectly set.
Spray plate blocked.
Inlet filters blocked.
Isolating valve partially
closed.
Plumbing system fault.
Electrical supply failure.
PCB failure.
Potentiometer failure.
Motor overheated,
thermal switch operated.
Reset maximum temperature.
Refer to COMMISSIONING.
Adjust cylinder temperature.
Note! It is recommended stored
water temperatures do not
exceed 65°C.
Reset maximum temperature.
Refer to COMMISSIONING.
Clean spray plate. Refer to the
instruction manual supplied with
the shower fittings.
Contact your installer.
Open valve.
Contact your installer.
Contact your installer.
Contact your installer.
Contact your installer.
If the thermal switch operates
repeatedly contact customer
service for further advice.