Status Indicator Leds; Dot-Matrix Display - evertz VistaLINK 7700 MultiFrame Manual

Telecom and datacom optical wavelength converter
Table of Contents

Advertisement

4.1.

STATUS INDICATOR LEDS

LOCAL FAULT:
This Red LED indicates poor module health and will be on if:
The LOCAL FAULT indication can also be reported to the frame through the
FRAME STATUS jumper.
LINE STATUS:
Red:
Green:
Yellow:
Off:
EQUIP STATUS:
Red:
Green:
Yellow:
Off:
4.2.

DOT-MATRIX DISPLAY

Additional signal and status monitoring is provided via the four-digit dot-matrix display located at the card-
edge. The card-edge pushbutton and toggle-switch are used to navigate through the display menu. Figure
4-2 provides a quick reference to the display menu structure.
Pressing the pushbutton advances the display to the next menu level. The toggle-switch may then be used
to move up or down through selections of that menu level. Select BACK to return to the top menu level.
CTRL menu items have user-adjustable configuration values associated with them. STAT menu items
display operating conditions or configuration values, but do not allow adjustment.
If a specific menu selection has a configuration value associated with it, then this may be changed using
the toggle switch. Pressing the pushbutton will apply the displayed value and return you to the previous
menu level.
The most recent user selection will be maintained in non-volatile memory in the event of power loss to the
module.
7707OO-2-OC Telecom and Datacom Optical Wavelength Converter
• There is absence of a valid LINE or EQUIPMENT input signal
• A local power fault exists (i.e. a blown fuse).
• LINE or EQUIPMENT laser fault
• Optical input power is reported as "OVER" on LINE or EQUIPMENT inputs
LINE laser fault
Locked on to a valid, recognized signal format on LINE input
LINE input is in non-reclock (bypass) mode
Signal is unrecognized, does not match data rate setting or is not
present at LINE input
EQUIPMENT laser fault
Locked on to a valid, recognized signal format on EQUIPMENT input
EQUIPMENT input is in non-reclock (bypass) mode
Signal is unrecognized, does not match data rate setting or is not
present at EQUIPMENT input