evertz VistaLINK 7700 MultiFrame Manual

Telecom and datacom optical wavelength converter

Advertisement

Quick Links

1.
OVERVIEW.......................................................................................................................................... 1
2.
INSTALLATION................................................................................................................................... 3
2.1. CARE AND HANDLING OF OPTICAL FIBER............................................................................ 4
2.1.1. Safety .............................................................................................................................. 4
2.1.2. Assembly......................................................................................................................... 4
2.1.3. Labeling........................................................................................................................... 4
2.1.4. Handling and Connecting Fibers ..................................................................................... 5
3.
SPECIFICATIONS............................................................................................................................... 6
3.1. OPTICAL INPUTS ...................................................................................................................... 6
3.2. OPTICAL OUTPUTS .................................................................................................................. 6
3.3. ELECTRICAL ............................................................................................................................. 7
3.4. PHYSICAL .................................................................................................................................. 7
4.
STATUS INDICATORS AND DISPLAYS ........................................................................................... 8
4.1. STATUS INDICATOR LEDS....................................................................................................... 9
4.2. DOT-MATRIX DISPLAY ............................................................................................................. 9
4.2.1. Displaying the Data Standard Detected at the LINE Input ............................................ 11
4.2.2. Displaying the Optical Power at the LINE Input ............................................................ 11
4.2.4. Displaying the Optical Power at the EQUIPMENT Input ............................................... 12
4.2.5. Displaying the Firmware Version................................................................................... 12
4.2.6. Selecting the Data Standard Mode ............................................................................... 13
4.2.7. Setting the Data Standard ............................................................................................. 13
4.2.8. Selecting the Output Laser Enable Mode...................................................................... 14
4.2.10. Resetting Factory Defaults ............................................................................................ 15
5.
JUMPERS AND LOCAL CONTROLS .............................................................................................. 16
BY THE GLOBAL FRAME STATUS ........................................................................................ 16
5.2. CONFIGURING THE MODULE FOR FIRMWARE UPGRADES .............................................. 16
6.
®
7707OO-2-OC Telecom and Datacom Optical Wavelength Converter

TABLE OF CONTENTS

? ............................................................................................................. 17
®
Revision 1.3
7700 MultiFrame Manual

Advertisement

Table of Contents
loading

Summary of Contents for evertz VistaLINK 7700 MultiFrame

  • Page 1: Table Of Contents

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter TABLE OF CONTENTS OVERVIEW............................1 INSTALLATION........................... 3 2.1. CARE AND HANDLING OF OPTICAL FIBER................4 2.1.1. Safety ..........................4 2.1.2. Assembly......................... 4 2.1.3. Labeling........................... 4 2.1.4. Handling and Connecting Fibers ..................5 SPECIFICATIONS..........................
  • Page 2 7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter 6.2. V LINK MONITORED PARAMETERS ................17 ISTA ® 6.3. V LINK CONTROLLED PARAMETERS ................18 ISTA ® 6.4. V LINK TRAPS ........................18 ISTA ® Figures Figure 1-1: 7707OO-2-OC Block Diagram......................2 Figure 2-1: 7707OO-2-OC Rear Panel .........................
  • Page 3 May 09 Information contained in this manual is believed to be accurate and reliable. However, Evertz assumes no responsibility for the use thereof nor for the rights of third parties, which may be affected in any way by the use thereof. Any representations in this document concerning performance of Evertz products are for informational use only and are not warranties of future performance, either expressed or implied.
  • Page 4 7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter WARNING Never look directly into an optical fiber. Non-reversible damage to the eye can occur in a matter of milliseconds. Do not hook up the 7707OO-2-OC DWDM cards directly to each other with a short fiber optic cable.
  • Page 5: Overview

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter OVERVIEW The 7707OO-2-OC is a VistaLINK enabled, optical to optical wavelength converter for telecom and ® datacom signals. Reclocking and data rate indication is provided for supported rates from 125 Mb/s to 3.187 Gb/s, as per the table below: Standard Data Rate...
  • Page 6: Figure 1-1: 7707Oo-2-Oc Block Diagram

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter OPTICAL OPTICAL RECEIVER TRANSMITTER Reclocking OC-3 / STM-1 OC-12 / STM-4 OC-48 / STM-16 Other telecom/datacom EQUIPMENT LINE Bypass SIDE SIDE OPTICAL OPTICAL RECEIVER TRANSMITTER Reclocking OC-3 / STM-1 OC-12 / STM-4 OC-48 / STM-16 Other telecom/datacom Bypass...
  • Page 7: Installation

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter INSTALLATION The 7707OO-2-OC comes with a companion rear plate that has four SC/PC (shown), ST/PC, FC/PC, or SC/APC optical connectors. For information on mounting the rear plate and inserting the module into the frame see the 7700FR chapter section 3.
  • Page 8: Care And Handling Of Optical Fiber

    2.1.1. Safety CLASS 1 LASER PRODUCT 2.1.2. Assembly Assembly or repair of the laser sub-module is done only at Evertz facility and performed only by qualified Evertz technical personnel. 2.1.3. Labeling Certification and Identification labels are combined into one label. As there is not enough room on the product to place the label it is reproduced here in the manuals.
  • Page 9: Handling And Connecting Fibers

    5 cm to avoid fiber-bending loss that will decrease the maximum attainable distance of the fiber cable. The Evertz fiber optic modules come with cable lockout devices, to prevent the user from damaging the fiber by installing a module into a slot in the frame that does not have a suitable I/O module.
  • Page 10: Specifications

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter SPECIFICATIONS 3.1. OPTICAL INPUTS Standards (reclocked): Standard Data Rate Telecom 2.488 Gb/s OC48/STM16 622 Mb/s OC12/STM4 OC3/STM1 155 Mb/s Gigabit Ethernet 1.25 Gb/s Datacom Fiber Channel 2.125 Gb/s 1.062 Gb/s Fiber Channel 531 Mb/s Fiber Channel...
  • Page 11: Electrical

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter Line Side: Wavelengths: Standard: 1310nm, 1550nm (nominal) CWDM: 1270nm to 1610nm (See ordering information) DWDM: C-Band/L-Band (ITU-T G.694.1 compliant) Output Power: 1310nm FP: -7dBm ± 1dBm 0dBm ± 1dBm CWDM: +7dBm ±...
  • Page 12: Status Indicators And Displays

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter STATUS INDICATORS AND DISPLAYS The 7707OO-2-OC has 4 LED Status indicators and a 4 digit alphanumeric display on the front card edge to show operational status of the card at a glance. The card edge pushbutton is used to select various displays on the alphanumeric display.
  • Page 13: Status Indicator Leds

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter 4.1. STATUS INDICATOR LEDS LOCAL FAULT: This Red LED indicates poor module health and will be on if: • There is absence of a valid LINE or EQUIPMENT input signal •...
  • Page 14: Figure 4-2: Card-Edge Menu Structure

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter Pushbutton Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 4 Indications LASR...ERR (Laser Error) Supersedes OK (Ay-Okay) Selections Selections Selections Indications Rates Per Mode RATE (Signal Rate) BYP (Bypass) LOS (Loss of Signal)
  • Page 15: Displaying The Data Standard Detected At The Line Input

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter 4.2.1. Displaying the Data Standard Detected at the LINE Input To display the data standard detected at the LINE input, select the STAT menu item in menu level 1, then use the toggle switch to display the LINE option and press the pushbutton to select it.
  • Page 16: Displaying The Data Standard Detected At The Equipment Input

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter 4.2.3. Displaying the Data Standard Detected at the EQUIPMENT Input To display the data standard detected at the EQUIPMENT input, select the STAT menu item in menu level 1, then use the toggle switch to display the EQUP option and press the pushbutton to select it. Use the toggle switch to then display the RATE option and press the pushbutton to select it.
  • Page 17: Selecting The Data Standard Mode

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter 4.2.6. Selecting the Data Standard Mode The data rates reclocked by the 7707OO-2-OC are grouped into Telecom and Datacom categories as follows: Standard Data Rate Telecom OC48/STM16 2.488 Gb/s OC12/STM4 622 Mb/s OC3/STM1 155 Mb/s...
  • Page 18: Selecting The Output Laser Enable Mode

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter CTRL Fiber Channel, 2.125 Gb/s FC-2125MBPS RATE Fiber Channel, 1.062 Gb/s FC-1062MBPS DCOM Fiber Channel, 531 Mb/s FC-531MBPS FC-2125MBPS Fiber Channel, 266 Mb/s FC-266MBPS FC-1062MBPS Fiber Channel, 133 Mb/s FC-133MBPS FC-531MBPS Fast Ethernet ETH-125MBPS...
  • Page 19: Resetting Factory Defaults

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter 4.2.10. Resetting Factory Defaults The 7707OO-2-OC may have all settings returned to factory defaults using a single menu control item. To reset to factory defaults, select the CTRL menu item in the first menu level. Use the toggle switch to select the FRST menu item and press the pushbutton.
  • Page 20: Jumpers And Local Controls

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter JUMPERS AND LOCAL CONTROLS Several jumpers, located at the front of the module are used to preset various operating modes. Figure 4-1 shows the locations of the jumpers. 5.1. SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME STATUS The FRAME STATUS jumper determines whether local faults (as shown by the Local Fault indicator) will be connected to the 7700FR frame's global status bus.
  • Page 21: Vistalink ® Remote Monitoring/Control

    1. An SNMP manager, also known as a Network Management System (NMS), is a computer running special software that communicates with the devices in the network. Evertz VL-Fiber demo Manager graphical user interface (GUI), third party or custom manager software may be used to monitor and control Evertz VistaLINK enabled fiber optic products.
  • Page 22: Vista Link ® Controlled Parameters

    7700 MultiFrame Manual 7707OO-2-OC Telecom and Datacom Optical Wavelength Converter 6.3. LINK CONTROLLED PARAMETERS ISTA ® The following parameters can be remotely controlled through the VistaLINK interface. ® Parameter Description Data Mode Select telecom or datacom data rates Select the data rate/standard from available telecom and datacom types, automatic and bypass Data Rate modes...

This manual is also suitable for:

Vistalink 7707oo-2-oc

Table of Contents