Table 22: Description Of The Marking Example Per Atex And Iecex - WAGO 750 XTR Manual

8do 24 vdc 0.5a lss 2-wire xtr 8-channel digital output; 24 vdc; 0.5 a; low-side switching; 2-wire connection; extreme
Hide thumbs Also See for 750 XTR:
Table of Contents

Advertisement

WAGO I/O System 750 XTR
750-1516/040-000 8DO 24 VDC 0.5A LSS 2-wire XTR

Table 22: Description of the Marking Example per ATEX and IECEx

Marking Text
TUEV 07 ATEX 554086 X
IECEx TUN 09.0001 X
Dust
II
3 D
Ex
tc
IIIC
T135°C
Dc
Mining
I
M2
Ex
d
I
Mb
Gases
II
3 G
Ex
nA
IIC
T4
Gc
Use in Hazardous Environments
Description
Approving authority or certificate numbers
Device group: All except mining
Device category 3 (Zone 22)
Explosion protection mark
Protection type: Protection by enclosure
Dust group: Explosive dust atmosphere
Maximum surface temperature of the enclosure
(no dust bin)
Level of equipment protection (EPL)
Device group: Mining
Device category: High degree of safety
Explosion protection mark
Protection type: Pressure-tight encapsulation
Electrical devices in potentially explosive mines
Level of equipment protection (EPL)
Device group: All except mining
Device category 3 (Zone 2)
Explosion protection mark
Protection type: Non-sparking equipment
Gas group: Explosive gas atmosphere
Temperature class: Max. surface temperature
135 °C
Level of equipment protection (EPL)
49
Manual
Version 1.0.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

750-1516/040-000

Table of Contents