Troubleshooting - Bruno ELECTRA-RIDE II Installation Manual

Table of Contents

Advertisement

UNIT FAILS TO
OPERATE
UNIT OPERATES
SLOWLY, LACKS
POWER
CONTROLS OPERATE
BACKWARDS AND UNIT
GOES "UP" SLOWLY
AND "DOWN" FAST
UNIT OPERATES
ERRATICALLY
OR
INTERMITTENTLY
WITH REMOTE
CALL/SEND
SRE-1550 02-09-2009
• Check circuit breaker. Reset if necessary.
• Check battery connections.
• Check to see if footrest safety switches have been
depressed.
Safety tray below footrest should slide freely not
stick in a position which could depress the safety
switches.
• Check battery charge. Battery voltage should be in a
range of 16-28 VDC.
• Check setting of speed control potentiometer.
• Check for loose connections.
• Check that charger is plugged in, turned on and
operating properly.
• Unit has been connected for left-hand operation but
is installed on the right-hand side of the stairs (or
vice versa).
• Make correct connections (see Reversing Operations
in the installation manual).
• Check all safety mechanisms, including swivel seat
safety switch.
• Change the delay setting on the receiver board to
900 mSec.
• Reorient the transmitter (to point directly at the
carriage).
• Consult your dealer, an experienced technician or
contact the Bruno Technical Service Department.
35
©2009,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®

TROUBLESHOOTING