Troubleshooting - Bruno ELAN SRE-3050G Operator's Manual

Straight stairlift
Table of Contents

Advertisement

Your SRE-3050 is not operating correctly. What should you do?
Before calling your Bruno dealer, refer to the solutions listed below. This could save you
an unnecessary service call!
• Seat swivel. Is the seat locked in the riding position?
• Power seat swivel. Did the power seat swivel fail to operate properly?
If so:
- Pivot the access panel out.
- Pull the quick-release pin.
- Manually swivel the seat back to the riding position.
- From the bottom, insert the quickrelease pin into
the hole closest to the pivot pin. The quick-release
pin should pass through the hole in the offset
swivel to lock the seat in position.
- Pivot the access panel back to its closed position.
- Contact your authorized Bruno service technician.
• Footrest. Is there an obstruction on the stairway
that the footrest is contacting?
• Carriage safety panels. Is there an obstruction on the stairway that the carriage
• Main circuit breaker (or fuse) panel of residence. Has a breaker tripped or a fuse
• Battery charger. A discharged battery will cause the carriage to move more slowly
• Visual check . Do you notice anything about your stairlift that is different or out of
place?
If your SRE-3050 continues to function improperly or not at all after completing the
preceding checklist, contact an authorized Bruno dealer to perform all required
service, repair and maintenance operations.
Bruno Independent Living Aids

TROUBLESHOOTING

safety panels are contacting?
until the voltage drops to the point where the controller will shut
off. If this should occur, pause for a moment, then run the carriage
down to exit the seat.
Partially charged batteries will run the carriage down, but not up.
Confirm that the charger is plugged into a live outlet and wait for
the batteries to charge. Red and green LED's are illuminated.
Is the battery charger plugged into a functional outlet? Do not use
outlets which are controlled by a wall switch.
Is the RED power light on?
Has the circuit breaker of the residence tripped? Has a fuse blown in
the electrical panel of the residence?
access panel
blown?
15
Insert in hole
closest to pivot
SRE-3050G OPERATOR 02-10-2023
pin.