Battery Charger Led's And Fuse - Bruno ELECTRA-RIDE II Installation Manual

Table of Contents

Advertisement

ELECTRICAL
Battery charger LED's
RED
ON
OFF
ON (5 sec.)
ON (5 sec.)
ON
ON
ON
SLOW BLINK
ON
ON
ON
OFF (Vfloat >27.4V)
ON
BLINK
ON
OFF
ON
BLINK
Battery Charger Fuse Replacement
power switch
©2009,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
charging
power
ready
on
YELLOW
OFF
ON (5 sec.)
OFF
SLOW BLINK
ON
ON
OFF
FAST BLINK
ON
If the charger is subject to a power line surge,
the AC input fuse may blow. Refer to the illus-
fuse
tration to the left for fuse location.
To replace fuse:
1. Turn OFF the battery charger power switch.
2. Remove power cord from wall outlet.
3. Twist the fuseholder cap and pull out to
remove the fuse.
4. Replace with the same size and type:
(Bussmann GMD-2A or equivalent) 2A,
Slo-Blow, 5x20 mm.
26
GREEN
charger not connected to
battery (AC power ON, no
battery connected)
battery disconnect situa-
tion detected (AC power
ON, battery disconnect);
10-second delay until yellow
and green LED's completely
off
charger at maximum volt-
age/delivering maximum
current
batteries close to being fully
charged
batteries fully charged
low voltage indication
battery defective or
heavily sulfated
bad connection or batteries
STATUS
SRE-1550 02-09-2009

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sre-1550