12. Take the ¼" blue flexible pipe (E) that caries the cold
filtered water output from the filter and rough out the
minimum amount of pipe needed to connect to the ¼"
x ¼" pushfit connector (F) found on the boiler inlet.
Mark the desired minimum pipe length with a
permanent pen.
We recommend cutting the ¼" blue flexible pipe
(E) at least 200mm longer than the required minimum
pipe length to allow the boiler to be serviced more
easily by your customer, otherwise remove
unnecessary/unneeded pipe length to keep the
installation tidy.
Cut the ¼" blue flexible pipe (E) to length cleanly and
squarely using a snip tool, sharp craft blade or similar.
13. Push the ¼" blue flexible pipe (E) fully and firmly into
the ¼" x ¼" pushfit connector (F).
14. Firmly and fully push the silicone outlet tube (K) over
the 8mm barbed stem x 3/8" male tap connector (L).
15. Screw the 8mm barbed stem x 3/8" male tap connector
(L) into the 3/8" female flexible 110°C hose tap
connector (X5)
you must ensure to use 3/8" the fibre seal (X5)
(supplied separately with the tap) is in this
connection.
WARNING: You must not directly connect the
tap hose (X5) directly to the boiler output (C). You
must always use output adaptor (J) and silicone
hose (K) to connect the tap.