Using The Product; Boiler Screen And Interface - PROBOIL .4E User's Installation Manual

Hide thumbs Also See for PROBOIL.4E:
Table of Contents

Advertisement

1.2 Using the product:

1.2
1.2
1.2
Using the product:
Using the product:
Using the product:

1.2.1 Boiler screen and interface:

The boiler uses a touch screen interface to both display and change the status of the boiler.
PROBOIL.4E user & installation guide v1d
Temperature adjust:
-
+
Touch sensitive
&
keys lower and raise the boilers maximum target temperature
between a selection of pre-set values 75, 85, 90, 95, 96, 97- 98°C
White colour, constantly illuminated when unit is not in standby mode, the boiler will
beep when pressed to acknowledge the command.
The water inside the boiler tank will not exceed 98° to ensure compliance to
local UK safety laws.
Standby:
P
Touch sensitive
key switches the unit between on and standby modes, press and
hold for approximately 1.5 seconds to activate.
When in standby mode the water inside the boiler will not be heated.
Touch sensitive, white colour, constantly illuminated when unit is not in standby mode,
flashes when in standby mode.
The boiler will beep when pressed to acknowledge the command.
Ready indicator:
Displays when the boiler is not in a heating phase indicating the water is at or near the
pre-set target temperature.
Blue colour, constant illumination when unit not in standby mode or the boiler is
heating.
11