Proboil.4E Installer Guide; Important Technical Data; Boiler; Filter Cartridge - PROBOIL .4E User's Installation Manual

Hide thumbs Also See for PROBOIL.4E:
Table of Contents

Advertisement

2 2 2 2 PROBOIL.
PROBOIL.
PROBOIL.4E 4E 4E 4E installer guide
PROBOIL.

2.1 Important technical data:

2.1
Important technical data:
2.1
2.1
Important technical data:
Important technical data:

Boiler:

Boiler:
Boiler:
Boiler:
Measure:
Model
Boiler type
Unit dimensions
Overall weight
Ambient operating temperature
Minimum cold input pressure
Maximum cold input pressure
Boiling tank capacity
Typical usable volume
Maximum Chlorine value for
incoming water
Tank material
Selectable in tank temperatures
Heat up time
Thermal loss
Safety devices
Supply voltage range
Max. Power usage
(element on)
Power usage Standby (screen off)
Power usage (keep warm at 98°C)
Power usage (reboil 1 litre at 98°C)
Power lead

Filter cartridge

Filter
Filter
Filter
cartridge: : : :
cartridge
cartridge
PROBOIL.4E user & installation guide v1d
installer guide
installer guide
installer guide
Comments:
PROBOIL.4E
Vented (unpressurised) displacement system
206x256x291mm (without connectors attached)
9 kg (Apx. when full)
+5°C to +40°C (indoor use heated space only)
2 bar (recommended), assuming a minimum acceptable flow rate of 1 litre
per minute.
5.5 bar, if incoming cold water pressure is above this value than a pressure
reducing valve must be installed.
4 Litres +/- 5%
Dependent on temperature selection, when set to 98°C approximately 3.0
litres above 90° and approximately 1.5 litres before incoming cold water
decrease the output temperature when dispensed continuously.
100mg/l
Stainless steel (304)
98° Maximum with adjustable heating point adjustment on screen
(75, 85, 90, 95, 96, 97- 98°C range)
From 20°C to 98°C
1 litre usage recovery, approximate time 18 minutes
2 litre usage recovery, approximate time 12 minutes
3 litre usage recovery, approximate time 8 minutes
4 litre usage recovery, approximate time 9 minutes
Up to apx. 100 UK cups per hour dependant on environmental and usage
conditions
Apx. 3-4°C. loss from tank to spout exit
Varies according to tap model, environmental and usage conditions
-
vented (unpressurised) tank
-
minimum water level float switch to prevent dry heating
-
digital thermal monitoring and control
-
digital self-diagnostic control
-
one shot dry burn 120°C thermal fuse (non-resettable)
-
blow off connection for accidental blockage protection
AC 220-240V (50Hz)
2.15kW at 240V AC
0.5W
0.043kWh, depending on ambient temperature, power on, no water usage.
0.1kWh (based on single 1 litre dispense of 98°C)
1.4M (cable), 3 pin UK plug (13A), IEC connector, do not extend or replace.