3) Add a short section of 15mm copper pipe (G1) to cold isolation valve.
4) Attach the three way tee (F11) using compression nut and olive (F10 & F12).
Key
Description & Qty
¾" x 3/8" push fit
F1
3/8" flexible blue
F2
inlet pipe
Filter head inlet
F3
White flush pipe
F4
F5
Filter cartridge
Filter head screws (x
F6
2)
3/8 stem x ¼" push
F7
fit adaptor
Push fit tee
F8
(4 in 1 tap only)
¼" NPTF x ¼" Push
fit connector
F9
(4 in 1 tap only)
F10
Olives (x 2)
F11
3 way tee
Compression nuts (x
F12
2)
*Parts (F1-F12) included with filter pack.
E1
¼" flexible blue inlet
E2
pipe
E3
*Parts (E1-E3) are cut down from one
piece (E) which is included with the boiler.
Filtered water adaptor nut
X1
(4 in 1 tap only)
X3
Cold flexi tail
*Parts (X1 & X3) are included with the tap.
G1
15mm copper pipe
G2
15mm copper pipe
Compression nuts x 2
G3
G4
Olives x 2
*Parts (G1-G4) are not included.
5) Attach another stub of 15mm pipe (G2) to the 15mm (1/2") outlet of the tee (F11) using compression nut and olive
(F10 & F12). The length of pipe (G2) will vary to allow connection to the taps cold flexible pipe (X3).
⚠
ensure that three way tee (F11) is in the closed position and that the lever is accessible to the customer.
6) Screw the ¾" x 3/8" push fit (F1) onto the three way tee (F11), ensuring the isolation valve lever is in the off position
as shown in the diagram.
PROBOIL.4E user & installation guide v1d
Spare part
Drawing
code
ASPT1031-F1
ASPT1031-F2
ASPT1031-F3
n/a
PT1024
ASPT1031-F6
ASPT1031-F7
ASPT1031-F8
ASPT1031-F9
ASPT1031-
F11
-
ASPT1030
E1
Note: Parts (E2, E3,F8, F9 & X1)
are for 4 in 1 taps only.
For 3 in 1 taps please connect
blue inlet pipe (E1) to the boiler.
36