PROBOIL .4E User's Installation Manual page 24

Hide thumbs Also See for PROBOIL.4E:
Table of Contents

Advertisement

20. Press and hold the
+
21. Use the
and
Change the pre-set water target temperature to 98°C
22. Wait for the PROBOIL.4E unit to display
"READY" onscreen
23. Take note of the time and wait for no longer than a further 10 minutes maximum (or as described on the
solution usage label) for the sterilising solution to work. It is normal for an odour to be present during this
time.
24. Turn the boiler back into standby mode using the
25. Turn on the 98°C water using the Hotkey, keep the Hotkey on for a minimum of 5 minutes to thoroughly flush
the boiler with fresh water.
26. Turn the boiler back on using
seconds and set it to the desired target
temperature, wait until the display shows
"READY".
27. If dirt, debris or taste remains then you can flush the tap for a further 5 minutes or longer as required.
PROBOIL.4E user & installation guide v1d
P
key for 1.5 seconds, this will turn the boiler back on from "standby" mode
-
key to change the target temperature on screen.
P
key for 1.5
P
key for 1.5 seconds
24

Advertisement

Table of Contents
loading

Table of Contents