wait until it has completely cooled off when replacing the Lamp Unit.
3. The lamp emits small amounts of UV-Radiation.
Avoid direct-eye contact by covering the Lamp and wearing the UV cut
protective glass.
4. The high pressure lamp involves a risk of explosion. Therefore, do not
touch the Lamp Bulb when servicing.
2. PREVENTION OF ELECTROSTATIC DISCHARGE
(ESD) TO ELECTROSTATICALLY SENSITIVE (ES)
DEVICES
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such
components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES
devices are integrated circuits and some field-effect transistors and semiconductor "chip"
components. The following techniques should be used to help reduce the incidence of component
damage caused by electro static discharge (ESD).
1. Immediately before handling any semiconductor component or
semiconductor-equipped assembly, drain off any ESD on your body by
touching a known earth ground. Alternatively, obtain and wear a
commercially available discharging ESD wrist strap, which should be
removed for potential shock reasons prior to applying power to the
unit under test.
Figure 2