Download Print this page

Panasonic PT-40LC12 Service Manual page 39

Multi media display
Hide thumbs Also See for PT-40LC12:

Advertisement

3. Set LAMP RUN TIME to the original value
1) Select LAMP RUN TIME in Service Mode (LCD Main
C.B.A. (1)).
2) Press the VOLUME UP/DOWN key on the remote to
change to the original value (value A) that was noted
before removing the Projection Unit at the user's location.
S E R V I C E
M O D E
T O T A L
T I M E
1 3 0 W
1 5 0 W
L A M P
R U N
T I M E
1 3 0 W
1 5 0 W
F I L T E R
T I M E
2 5 0 2 : 1
9 0 0 2 : 1
2 7 0 6 : 1
< Service Mode (LCD Main C.B.A. (1)) >
4. Set FILTER TIME to the original value
1) Select FILTER TIME in Service Mode (LCD Main C.B.A.
(1)).
2) Press the VOLUME UP/DOWN key on the remote to
change to the original value (value B) that was noted
before removing the Projection Unit at the user's location.
Note:
If the Air Filter is cleaned, reset the FILTER TIME
(change to "0" (value B)).
R E S E T
1
5 5 3 5 h
0 h
5 3 5 h
Value A
5 3 5 h
(changeable)
0 h
Value B
1 9 0 h
(changeable)
2 3 0 3 : 1
2 3 0 5 : 1
Fig. 4-9