Figure 25: BSBAC 1 HP drive motor connection - exploded view
Bastian Solutions highly recommends using a lift table or equivalent equipment to
remove the motor from the drive section. Improper handling of the motor can cause
damage and increase risk of injury.
7. Remove the underside cover closest to the drive pulley from the drive section. The underside
cover closest to the drive pulley is attached by (4) 3/8" carriage bolts and serrated flange nuts and
(4) 1/4" hex head cap screws and clip on nuts. Figure 26 illustrates the location of the underside
cover and corresponding hardware on the motor side. The non-motor side is identical except for
the shaft length of the drive pulley.
Published January 2022
Installation & Maintenance Manual: BSBAC 1 HP
1 HP drive
pulley
Torque arm
Rev. B
AC drive
motor and
b
7/16" hex
head cap
M8 shoulder