SRAM RockShox Super Deluxe Coil Service Manual page 38

Table of Contents

Advertisement

19
Install the Schrader valve into the IFP reservoir cap.
20
Install the RockShox air valve adaptor tool onto the shock pump and
thread the adaptor tool into the reservoir air valve. Inflate the reservoir
to 200 psi.
Remove the adaptor tool and pump from the reservoir.
Separating the pump from the adapter first will allow all of the air to
escape from the reservoir.
You may substitute nitrogen if you have the proper fill equipment.
21
Install a new IFP reservoir fill cap o-ring, and install the fill cap into the
IFP reservoir cap.
22
Turn the outer compression tool clockwise to remove pressure on the
system. Remove the spring retainer and both compression tools from
the damper body.
RockShox Air Valve Adapter Tool and Shock Pump
Schrader Valve Core Tool
Super Deluxe Coil Assembly and Bleed
Schrader Valve Core Tool
200 psi
38

Advertisement

Table of Contents
loading

Table of Contents