Download Print this page

Heartland VALUE CLASSIC Assembly Manual page 51

Advertisement

PARTS REQUIRED:
7/16 x 23-7/8 x 48"
x1
(1,1 x 60,6 x 121,9 cm)
3
Install a 23-7/8" x 48" roof panel flush to the
installed panel and flush at peak (Fig. B).
Secure panel with (1) 2" nail in each corner.
4
Move the gable end rafter edge until it
is 1/2" from the 23-7/8" x 48" roof panel
(Fig. A).
Finish securing panel with (1) 2" nail in
each corner.
5
Maintain spacing between the center of the rafters
at the lower edge of the panels (Fig. D).
Secure panels with (1) 2" nail into each rafter,
as shown.
Move to the top of the panel and keep spacing
between the center of the rafters.
Secure panels with (1) 2" nail into each rafter.
24-3/8"
(61,9 cm)
10' x 10' ROOF PANELS
Fig. A
Gable
End Rafter
NOTE:
Measurements from inside of gable panels
24"
(60,9 cm)
2" (5,1 cm) Nails
1/2"
(1,2 cm)
Flush
Fig. D
24"
24"
(60,9 cm)
(60,9 cm)
49
x10
2" (5,1 cm)
Flush at
Fig. B
One 2" Nail
in each
corner
24-3/8"
(61,9 cm)
peak

Advertisement