Connect 10/100/1000Base-T Ports - WAGO 852-1328 Product Manual

Industrial managed 6 ports 1000base-t; 2 slots 1000base-sx/lx; mac security
Hide thumbs Also See for 852-1328:
Table of Contents

Advertisement

Connection
There are various types of multi-mode, single mode or WDM SFP modules. Follow the
steps below to connect the fiber optic cable properly:
Note
Rubber covers
Remove and safely store the rubber covers of the fiber optic port (LC).
If no fiber optic cable is connected, the rubber cover should be installed to protect the
fiber optics.
1. Insert the respective SFP modules.
2. Ensure that the fiber optic ports are clean. You can clean the cable connectors by
wiping them with a clean cloth or a cotton ball soaked with a little ethanol. Dirty fiber
optic cables affect the quality of the light transmitted via the cable and leads to re-
duced performance at the port.
3. Connect one end of the fiber optic cable to the LC port of the industrial managed
switch and the other end to the fiber optic port of the other device.
4. Check the respective port LED on the industrial managed switch that the connection
is established (see Section

9.4 Connect 10/100/1000BASE-T ports

The 10/100/1000BASE-T ports (RJ-45 ETHERNET ports) of the support both autosens-
ing and auto-negotiation.
1. Connect one end of the twisted pair cable of the type Category 3/4/5/5e to an avail-
able RJ-45 port on the and the other end to the port of the selected network node.
2. Check the respective port LED on the that the connection is established (see Section
8 Port LEDs
28
Product manual | Version: 1.2.0
Industrial Managed Switch
Proper connection of the fiber optic cable to the SFP mod-
Note
ule
For a proper connection, snap the connector of the fiber optic cable into the SFP module
audibly.