Secure Code - WAGO 852-1328 Product Manual

Industrial managed 6 ports 1000base-t; 2 slots 1000base-sx/lx; mac security
Hide thumbs Also See for 852-1328:
Table of Contents

Advertisement

Configuration in the WBM
Parameters
Enabled
SCI
SAK

10.6.2 Secure Code

Every WAGO industrial managed switch will have eight secure codes. Every code has
three characters. The security codes of every switch are unique. An example of secure
code is illustrated in Figure "Example of Secure Codes". They can be used to log in to the
industrial managed switch when the user forgot the password and selected the [Forget
it] button at the login dialog.
The use of the device recovery card is enabled by default.
To disable this secure code mechanism, uncheck the Enable box and click [Submit] but-
ton as shown in Figure "WBM "Security" Page – "Secure Code" Tab". Please refer the
WAGO login in Section „Login Failure" for more detail.
10.6.3 802.1X (IEEE 802.1X)
The 802.1X tab under the Security page is subdivided into three sub-tabs which are: Set-
ting, Parameters Setting, and Port Setting as shown below.
62
Product manual | Version: 1.2.0
Industrial Managed Switch
Factory Default
Description
Uncheck
Check the box to enable static secure association key (SAK)
mode of MACSec for the selected port(s) on the switch.
0
Secure Channel Identifier (SCI) is a 16-digit hexadecimal number.
Note that if the user did not configure all digits of SCI, all remain-
ing digits will be auto-configured to 0s.
0
Secure Association Key (SAK) is a 32-digit hexadecimal number.
Note that if the user did not configure all digits of SAK, all remain-
ing digits will be auto-configured to 0s.
Figure 46: Example of Secure Codes
Figure 47: WBM "Security" Page – "Secure Code" Tab
852-1328

Advertisement

Table of Contents
loading

Table of Contents