H8S, H8SX Family E10A-USB Emulator
Performance-measurement settings should be made in the [Performance Analysis] dialog box.
The [Performance Analysis] dialog box contains the following items.
[Channel 1] group box: Settings on PA1
[Don't care] checkbox
R20UT2526EJ0300 Rev. 3.00
Mar 14, 2013
Figure 2.7 [Performance Analysis] Dialog Box
Selected:
Performance measurement will not be performed on PA1.
Not selected:
Performance measurement will be performed on PA1.
PA1 is for measuring the number of execution cycles in the
entire program.
Section 2 Specification of the Emulator's Software