Installation Method; Installation Into Housing; Wiring Method; Position And Rating Of Terminals - Takex PXB-50HF-KH Instruction Manual

Photoelectric beam sensor
Table of Contents

Advertisement

4

INSTALLATION METHOD

4-1

INSTALLATION INTO HOUSING

Read the instruction manual for your housing carefully, and install the product into the housing correctly.
Wiring is required based on the sensor installation.
Refer to "6 WIRING METHOD" for wiring and connection.
Refer to "9 EXPLANATION OF FUNCTIONS" for switching channels and transmitting beam power.
Housing
(Frame)
5

WIRING METHOD

5-1

POSITION AND RATING OF TERMINALS

Power input
1
(no polarity)
2
Current consumption: PXB- 50HF-KH: 9mA
5-2

WIRING DISTANCE BETWEEN SENSOR AND POWER SUPPLY

Part No.
Size of
electrical cable used
AWG 20 (Dia,0 . 8 mm)
Up to 2,500ft. ( 750m) Up to 17,000ft. ( 5,200m) Up to 2,300ft. ( 700m)
AWG 18 (Dia,1 . 0 mm)
Up to 3,800ft. (1,160m) Up to 27,500ft. ( 8,380m) Up to 3,700ft. (1,130m)
AWG 17 (Dia,1 . 1 mm)
Up to 4,800ft. (1,460m) Up to 33,000ft. (10,000m) Up to 4,500ft. (1,370m)
AWG 16 (Dia,1.25 mm)
Up to 6,200ft. (1,890m) Up to 43,000ft. (13,100m) Up to 5,800ft. (1,770m)
AWG 15 (Dia,1 . 4 mm)
Up to 7,800ft. (2,380m) Up to 53,000ft. (16,000m) Up to 7,300ft. (2,350m)
AWG 14 (Dia,1 . 6 mm)
Up to 10,000ft. (3,000m) Up to 71,000ft. (21,600m) Up to 9,500ft. (2,900m)
When 2 or more units are connected, the wiring distance is calculated as follows: [Above value/number of units]
<Transmitter>
12 to 30V DC
PXB-100HF-KH:11mA
PXB-200HF-KH:13mA
PXB-50HF-KH
12V DC
24V DC
Panhead screw
(M3×12mm)
: 4 pcs
(ACCESSORIES)
<Receiver>
Power input
(no polarity)
1
Current consumption: PXB- 50HF-KH: 21mA
2
COM
3
Alarm output
30V (AC/DC) 0.25A (Resistance load)
4
No-voltage relay contact: c contact
NC
Built-in contact protection resistance
5
NO
COM
Environmental output
6
30V (AC/DC) 0.25A (Resistance load)
7
No-voltage relay contact: c contact
NC
Built-in contact protection resistance
8
NO
Alarm memory control input
9
10
Auto gain lock control
11
PXB-100HF-KH
12V DC
24V DC
Up to 16,000ft. ( 4,880m) Up to 2,200ft. ( 670m)
Up to 25,000ft. ( 7,500m) Up to 3,500ft. (1,070m)
Up to 31,000ft. ( 9,500m) Up to 4,200ft. (1,280m)
Up to 40,000ft. (12,000m) Up to 5,300ft. (1,600m)
Up to 51,000ft. (15,500m) Up to 6,800ft. (2,070m)
Up to 66,000ft. (20,000m) Up to 8,900ft. (2,710m)
12 to 30V DC
PXB-100HF-KH: 21mA
PXB-200HF-KH: 21mA
PXB-200HF-KH
12V DC
24V DC
Up to 15,000ft. ( 4,570m)
Up to 24,000ft. ( 7,320m)
Up to 29,500ft. ( 8,990m)
Up to 38,000ft. (11,600m)
Up to 47,000ft. (14,300m)
Up to 62,000ft. (18,900m)