Optical Axis Fine Adjustment Using The Monitor Output Voltage; Optical Axis Fine Adjustment Using The Alignment; Wireless Checker (Sold Separately) - Takex PXB-50HF-KH Instruction Manual

Photoelectric beam sensor
Table of Contents

Advertisement

Optical Axis Fine Adjustment Using the Monitor Output Voltage

<<Caution>>
First, check only the transmission on the upper level and reception on the upper level , and then check only the transmission on the
lower level and reception on the lower level.
(The values are not displayed correctly when the light can be received for both the upper and lower levels.)
See the following table for the monitor output voltage.
Monitor Output Voltage
More than 2.5 V DC
2.3 to 2.5V DC
Less than 2.3V DC
1. Insert a commercially available tester into the monitor
jack on the receiver.
<<Caution>>
The monitor jack is polarized.
Check the polarity of the tester pin before inserting it.
Use a tester with an internal resistance of over 100 kΩ.
2. Fine adjust the upper level optical axis.
(1) Press the upper/lower changeover switch
on the transmitter to select [Only transmit
from upper].
(2) Press the upper/lower changeover switch
on the receiver to select [Reception
authorization on upper only].
(3) Turn the adjustment screw to fine adjust
until the monitor output voltage reaches
the highest value.
(Adjust both the transmitter and receiver.)
3. Fine adjust the lower level optical axis.
(1) Press the upper/lower changeover switch
on the transmitter to select [Only transmit
from lower].
(2) Press the upper/lower changeover switch
on the receiver to select [Reception
authorization on lower only].
(3) Turn the adjustment screw to fine adjust
until the monitor output voltage reaches
the highest value.
(Adjust both the transmitter and receiver.)
4. Check if the light from another transmitter enters the receiver.
(1) Press the upper/lower changeover switch on the transmitter to
select [No transmission].
(2) Press the upper/lower changeover switch on the receiver to
select [Reception authorized for both upper and lower].
(3) Check that the alarm LED lights up when the receiver
outputs an alarm signal, and that the sensitivity attenuation
LED also lights up. Also check the monitor output voltage.
If no alarm is activated or the sensitivity attenuation LED is not lit
When using multi-level protection, the monitor output voltage
may become close to "1 V" due to effects of other photoelectric
beam sensors. In such case, readjust the other photoelectric
beam sensors to reduce the effects to the minimum possible.
In addition, check that an appropriate channel is set.
Optical Axis Fine Adjustment Using the Alignment Wireless Checker: ER-02 (Sold Separately)
Accurate adjustments of the optical axis can be achieved by checking the light reception level value using the voltage of the monitor output.
As the light reception level value can also be checked using the voltage on the transmitter, more accurate adjustments of the optical axis can be
achieved.
Using the alignment wireless checker enables easy and accurate beam alignment.
Providing sufficient margin of sensitivity increases resistance to the dense fog, snow, and heavy rain, which makes it possible to construct a
highly reliable intrusion alarm system.
Note: For detailed operation procedure of the alignment wireless checker, refer to the instruction manual for the alignment wireless checker ER-02.
Light Sensitivity
Best
Good
Poor, re-adjust
Transmitter
Transmitter
Accurate adjustments of the optical axis can be achieved by checking
the light reception level value using the voltage of the monitor output.
Lit
Bleep
(High-pitched
tone)
Bleep
Lit
(High-pitched
tone)
Transmitter
Off
Receiver
Monitor
Receiver
Lit
Monitor
Receiver
Lit
Monitor
Receiver
Lit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxb-100hf-khPxb-200hf-kh

Table of Contents