CAUTIONS ON INSTALLATION

・Avoid strong light from the
・Remove all
sun, antomobile headlights etc.
obstructions (trees,
directly shining on sensor.
clothes lines, etc.)
 When strong light stays in the
between sensor and
optical axis for a long time, it
re ector.
dose not cause malfunction but
will affect the product life.
PROTECTION DISTANCE
Outdoor 3.3' to 36' (1 to 11m)
Indoor
*Protection distance (between sensor/re ector)
 should be placed in the rated range.
*Sensitivity allowance will be greatly decreased when the protection distance deviates from the rated range.
(See the sensitivity allowance-protection distance curve for PB-11BE)
BEAM ALIGNMENT
・Fine tuning using a volt meter is required. (See section 5)
HEIGHT OF INSTALLATION
Install the sensor at a height of 31" to 39" (80 to
100cm) to catch a human target.
(Install vertically so that the center of the sensor
lens and middle part of the re ector assembly are
placed at the same height.)
POSITION OF INSTALLATION
Using the adjustments, the lens can move
horizontally (±90 degrees) and vertically (±10
degrees) allowing the unit to work in all
directions.
(example 1 to 3)
±10°
Vertical
adjustment
screw
±90°
EXPANSION OF BEAM
Sensor
・Do not install the unit
on places where it
may be splashed by
dirty water or direct
sea spray.
3.3' to 49' (1 to 15m)
*The sensor and re ector units should be installed uprightly and vertically.
Horizontal-adjustment
protection distance
・Do not install the
unit on unsteady
surfaces.
times
80
60
40
20
3 .3 '
( 1 m)
31" to 39"
(80 to 100m)
Example 1
Example 2
Make sure that the re ector's front side faces the sensor as illustrated.
A
Reflector
・Do not place highly
re ective objects
between the sensor and
the re ector as they are
likely to create a
protection loop and
prevent the sensor from
making a detection.
Sensitivity allowance-protection
distance curve for PB-11BE
1 3 '
3 6 '
( 4 m )
( 1 1 m )
CAUTIONS ON INSTALLATION
・Avoid over head wiring.
・When installing indoors, wiring procedures
similar to those for telephone or intercoms
are acceptable. Outdoor wires should be
placed inside conouit, or underground
cable/metal shielded cable should be used.
Example 3
(When BL-11 optional is used)
Expansion of beam can be calculated as follows.
A=0.03×
16.5' (5m)
5.9' (0.15m)
36.3' (11m)
13" (0.33m)
・Hazardous weather such
as heavy rain or frost may
cause false alarms.
 Sensitivity allowance of
re ective type beam
sensors is comparatively
lower than that of
standard type beams.
Protection distance→
A